Philips Symbol Library Page Two

    Introduction to the Symbol Library, Page Two


    This symbols library provides definitions for symbols that are used without accompanying text in the labeling for Philips medical devices.

    The entries are organized into categories on two pages:
     

    Controls

    Movement related
    Electricity and electronics

    Light and optics

    Miscellaneous

    Classification and identification of equipment

    Safety signs

    Transport, handling, and packaging

    Information and communication

    X-ray

    Medical instruments and blood processing

    Proprietary symbols - IGT Systems

    Patient monitoring

     

    References to international standards are in a brief form. The full references are below:
     

    IEC TR 60878:2015 (ed. 3.0), Graphical symbols for electrical equipment in medical practice

    IEC 60417:2002 DB, Graphical symbols for use on equipment

    ISO 7010:2011, Graphical symbols – Safety colours and safety signs – Registered safety signs.

    ISO 7000:2014 (ed. 5.0), Graphical symbols for use on equipment -- Registered symbols

    EN 50419:2006, Marking of electrical and electronic equipment in accordance with Article 11(2) of Directive 2002/96/EC (WEEE) 

     

    X-Ray

    Reference
    Symbol
    Name
    Definition
    Note
    Biplane Fluoroscopy
    Biplane Fluoroscopy
    Biplane Fluoroscopy
    Selects biplane fluoroscopy
    combines IEC 60417 5330 and 5364
    Fluoroscopy
    Missing Symbol
    Fluoroscopy
    Selects fluoroscopy acquisition
    IEC 60417 5330 (the eye) plus other elements
    Fluoroscopy Flavor 1
    Missing Symbol
    Fluoroscopy Flavor 1
    Selects the fluoroscopy flavor
    IEC 60417 5330 (the eye) plus other elements
    Fluoroscopy Flavor 2
    Missing Symbol
    Fluoroscopy Flavor 2
    Selects the fluoroscopy flavor
    IEC 60417 5330 (the eye) plus other elements
    Fluoroscopy Flavor 3
    Missing Symbol
    Fluoroscopy Flavor 3
    Selects the fluoroscopy flavor
    IEC 60417 5330 (the eye) plus other elements
    Frontal Fluoroscopy
    Missing Symbol
    Frontal Fluoroscopy
    Selects fluoroscopy on the frontal channel
    Combines IEC 60417 5330 and 5338
    IEC 60417-5330
    5364
    Radioscopy
    To identify controls or indicators for radioscopy (fluoroscopy).
    IEC 60417-5337
    5337
    X-ray tube
    To indicate a reference to the X-ray tube, for example to identify the surface of a component such as a focused anti-scatter grid, that has to be oriented towards the X-ray tube.
    IEC 60417-5338
    Missing Symbol
    X-ray source assembly
    To indicate a reference to an X-ray source assembly.
    Lateral Fluoroscopy
    Lateral Fluoroscopy
    Lateral Fluoroscopy
    Selects fluoroscopy on the lateral channel
    IGT: combined rotation IEC 60417 x-ray tube.  Reference in IGT doc is incorrect; doesn't match symbol
    IEC 60417-5339
    5339
    X-ray source assembly, emitting
    To indicate the emission or the imminent emission of X-radiation.
    IEC 60417-5364
    5364
    Radiodiagnostic simultaneous bi-plane operation
    To indicate a reference to simultaneous operation of two X-ray tubes.
    IEC 60417-5376
    5376
    X-ray image intensifier
    To indicate a reference to an X-ray image intensifier.
    IEC 60417-5385
    5385
    Beam limiting device, open
    To identify controls for opening the beam limiting device or to identify its partially or fully open state.
    IEC 60417-5392
    5392
    Patient support, tilting
    To identify the control for tilting the patient support or examination table.
    IEC 60417-5395
    5395
    Patient support, orthogonal movement to its plane
    To identify the control for the movement orthogonal to the plane of the patient support (table height).
    IEC 60417-5396
    5396
    Patient support, movements in its plane
    To identify controls for movements in the plane of the patient support.

    Medical instruments and blood processing

    Reference
    Symbol
    Name
    Definition
    Note
    2725
    2725
    Contains or presence of
    On medical devices: to indicate that the equipment contains the identified product or substance.

    Proprietary Symbols - IGT Systems

    Reference
    Symbol
    Name
    Definition
    Note
    Accept
    Accept
    Accept
    Moves the stand to the position indicated in the user interface
    Accept (alternate)
    Accept (alternate)
    Accept (alternate)
    Moves the stand to the position indicated in the user interface
    Copy to Reference 1
    Copy to Reference 1
    Copy to Reference 1
    Copies the image to the Reference 1 viewer window
    Copy to Reference 2
    Copy to Reference 2
    Copy to Reference 2
    Copies the image to the Reference 2 viewer window
    Copy to Reference 3
    Copy to Reference 3
    Copy to Reference 3
    Copies the image to the Reference 3 viewer window
    Cradle Left
    Cradle Left
    Cradle Left
    Cradles the table to the left
    Cradle Right
    Cradle Right
    Cradle Right
    Cradles the table to the right
    Disable Movement
    Disable Movement
    Disable Movement
    Disables geometry movements
    Emergency Stop
    Emergency Stop
    Emergency Stop
    Stops all geometry movements
    File Overview
    File Overview
    File Overview
    Displays an overview of the file
    File Replay
    File Replay
    File Replay
    Replays the file as a movie
    Fluoro Store
    Fluoro Store
    Fluoro Store
    Stores the displayed fluoroscopy images
    Frontal Stand
    Frontal Stand Rotation
    Frontal Stand
    Selects the frontal stand
    Frontal Stand Angulation
    Missing Symbol
    Frontal Stand Angulation
    Sets the angulation of the frontal stand
    Frontal Stand Rotation
    Frontal Stand Rotation
    Frontal Stand Rotation
    Rotates the frontal stand
    Image Subtraction
    Image Subtraction
    Image Subtraction
    Activates the Subtraction function
    Landmarking
    Landmarking
    Landmarking
    Activates the Landmarking function
    Lateral Stand
    Lateral Stand
    Lateral Stand
    Selects the lateral stand
    Lateral Stand Rotation/Angulation
    Lateral Stand Rotation
    Lateral Stand Rotation/Angulation
    Sets the angulation/rotation of the lateral stand
    Move Left Wedge
    Move Left Wedge
    Move Left Wedge
    Moves the left wedge
    Move Right Wedge
    Move Right Wedge
    Move Right Wedge
    Moves the right wedge
    Move Stand Laterally
    Move Stand Laterally
    Move Stand Laterally
    Moves the stand in a lateral direction
    Move Stand Longitudinally
    Move Stand Longitudinally
    Move Stand Longitudinally
    Moves the stand in a longitudinal direction
    Next Image
    Next Image
    Next Image
    Displays the next image
    Next Page
    Next Page
    Next Page
    Displays the next page of images in overview mode
    Next Series
    Next Series
    Next Series
    Displays the next series
    Park Stand
    Park Stand
    Park Stand
    Rotates the stand in the direction indicated to the park position
    Park Stand 2
    Park Stand 2
    Park Stand 2
    Rotates the stand in the direction indicated to the park position
    Pivot Lock
    Pivot Lock
    Pivot Lock
    Locks/unlocks the table pivot function
    Exposure
    Exposure
    Exposure
    Selects exposure acquisition.
    Previous Image
    Previous Image
    Previous Image
    Displays the previous image
    Previous Page
    Previous Page
    Previous Page
    Displays the previous page of images in overview mode
    Previous Series
    Previous Series
    Previous Series
    Displays the previous series
    Reset Buzzer
    Reset Buzzer
    Reset Buzzer
    Resets the fluoroscopy buzzer
    Reset Stand
    Reset Stand
    Reset Stand
    Resets the stand to the default position
    Roadmap
    Roadmap
    Roadmap
    Activates the Roadmap function
    Rotate Detector
    Rotate Detector
    Rotate Detector
    Rotates the detector
    Rotate Left Wedge
    Rotate Left Wedge
    Rotate Left Wedge
    Rotates the left wedge
    Rotate Right Wedge
    Rotate Right Wedge
    Rotate Right Wedge
    Rotates the right wedge
    Select Current Image as Mask
    Select Current Image as Mask
    Select Current Image as Mask
    Selects the currently displayed image as the mask for the Subtraction function
    Select Exposure Channel
    Exposure Channel
    Select Exposure Channel
    Selects the channel for exposure acquisition
    Series
    Series
    Series
    Displays/indicates a series
    Series Overview
    Series Overview
    Series Overview
    Displays an overview of the series
    Series Replay
    Series Replay
    Series Replay
    Replays the series as a movie
    SID
    Missing Symbol
    SID
    Sets the source-to-image distance
    Single Image
    Missing Symbol
    Single Image
    Displays/indicates an image
    Battery
    Missing Symbol
    Battery
    Indicates the charge level of the battery.
    SmartMask
    Missing Symbol
    SmartMask
    Activates the SmartMask function
    Snapshot
    Missing Symbol
    Snapshot
    Creates a snapshot (image file)
    Swivel Backward
    Missing Symbol
    Swivel Backward
    Swivels the table backward
    Swivel Forward
    Missing Symbol
    Swivel Forward
    Swivels the table forward
    Video On
    Missing Symbol
    Video On
    Switches on the video displays without powering on the full system
    Viewpad Focus
    Missing Symbol
    Viewpad Focus
    Switches control to the viewpad

    Patient monitoring

    Reference
    Symbol
    Name
    Definition
    Note
    IEC 60878 5643
    5643
    Zero line shift
    To identify the control to shift the zero line in a positive or negative direction.
    • Note 1 – To indicate a shift of the zero line in one direction only omit the other arrow.
    IEC 60878 5647
    5647
    Display in cascade
    To identify the control or the indicator for displaying one channel in a cascade mode, for example on a medical monitoring equipment, to follow characteristics of a patient, such as electrocardiogram (ECG).
    IEC 60878 5648
    5648
    Display transfer
    To identify the control or the indicator for transfering the display parameters from one channel to another, for example, on patient monitoring equipment, for moving the ECG signal from the upper channel to the lower channel.
    IEC 60878 5652
    5652
    Baseline adjustment
    To identify the control or the indicator for adjusting the baseline.
    IEC 60878 5653
    5653
    Baseline reset to a determined value
    To identify the control which compensates for deviations, in order to reset the displayed base level, e.g. to a specific set point.
    IEC 60878 5647
    5647
    Trend
    To indicate a reference to trend information.
    IEC 60878 5658
    5658
    Distance measurement
    To identify the control or the indicator for measuring a distance.
    IEC 60878 5795
    5795
    ECG triggered display
    To identify the control or the indicator for the display of electrocardiogram (ECG) triggered sequences.
    IEC 60878 5737
    5737
    Respiratory triggering
    To identify the control or the indicator to select respiratory triggering, for example on lithotripsy equipment for the release of shockwaves.
    IEC 60878 5649
    5649
    ALARMS LIMITS
    To identify the control to display or set ALARM LIMITS.
    IEC 60878 5650
    5650
    Upper ALARMS LIMIT
    To identify the control to display or set the upper ALARM LIMIT.
    IEC 60878 5651
    5651
    Lower ALARMS LIMIT
    To identify the control to display or set the lower ALARM LIMIT.