The complexity of structural heart disease interventions such as edge-to edge mitral valve repair requires integration of multiple highly technical imaging modalities. Real time imaging with 3-dimensional (3D) echocardiography is a relatively new technique that first, allows clear volumetric imaging of target structures such as the mitral valve for both pre-procedural diagnosis and planning in patients with degenerative or functional mitral valve regurgitation. Secondly it provides intra-procedural, real-time panoramic volumetric 3D view of structural heart disease targets that facilitates eye-hand coordination while manipulating devices within the heart. X-ray fluoroscopy and RT 3D TEE images are used in combination to display specific targets and movement of catheter based technologies in 3D space. This integration requires at least two different image display monitors and mentally fusing the individual datasets by the operator. Combined display technology such as this, allow rotation and orientation of both dataset perspectives necessary to define targets and guidance of structural disease device procedures. The inherently easy concept of direct visual feedback and eye-hand coordination allows safe and efficient completion of MitraClip procedures. This technology is now merged into a single structural heart disease guidance mode called EchoNavigatorTM (Philips Medical Imaging Andover, MA). These advanced imaging techniques have revolutionized the field of structural heart disease interventions and this experience is exemplified by a cooperative imaging approach used for guidance of edge-to-edge mitral valve repair procedures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

Abbreviations

3D:

3-dimensional

FOV:

field of view

LAA:

left atrial appendage

MV:

mitral valve

RT3D-TEE:

real-time 3-dimensional transesophageal echocardiography

TEE:

transesophageal echocardiography

References

Papers of particular interest, published recently, have been highlighted as: • Of importance •• Of major importance

  1. Feldman T, Wasserman HS, Herrmann HC, et al. Percutaneous mitral valve repair using the edge-to-edge technique: six-month results of the EVEREST Phase I Clinical Trial. J Am Coll Cardiol. 2005;46:2134–40.

    Article  PubMed  Google Scholar 

  2. Nkomo VT, Gardin JM, Skelton TN, Gottdiener JS, Scott CG, Enriquez-Sarano M. Burden of valvular heart diseases: a population-based study. Lancet. 2006;368:1005–11.

    Article  PubMed  Google Scholar 

  3. Webb JG, Pasupati S, Humphries K, et al. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation. 2007;116:755–63.

    Article  PubMed  Google Scholar 

  4. Feldman T. Intraprocedure guidance for percutaneous mitral valve interventions: TTE, TEE, ICE, or X-ray? Catheter Cardiovasc Interv. 2004;63:395–6.

    Article  PubMed  Google Scholar 

  5. Gill EA, Liang DH. Interventional three-dimensional echocardiography: Using real-time three-dimensional echocardiography to guide and evaluate intracardiac therapies. Cardiol Clin. 2007;25:335–40.

    Article  PubMed  Google Scholar 

  6. Abstracts of the Annual symposium of Transcatheter Cardiovascular Therapeutics, October 22-27,2006, Washington, DC, USA. Am J Cardiol 2006;98:1M-250M.

    Google Scholar 

  7. McKendrick R, Owada CY. Real-time 3D echocardiography-guided transcatheter device closure of atrial septal defects. Catheter Cardiovasc Interv. 2005;65:442–6. discussion 447.

    Article  PubMed  Google Scholar 

  8. Lange A, Palka P, Burstow DJ, Godman MJ. Three-dimensional echocardiography: historical development and current applications. J Am Soc Echo. 2001;14:403–12.

    Article  CAS  Google Scholar 

  9. Piccard M. Three-Dimensional Echocardiography. London: Informa Healthcare; 2007.

    Google Scholar 

  10. Zamorano J, Perez de Isla L, Sugeng L, et al. Non-invasive assessment of mitral valve area during percutaneous balloon mitral valvuloplasty: role of real-time 3D echocardiography. Eur Heart J. 2004;25:2086–91.

    Article  PubMed  Google Scholar 

  11. Silvestry FE, Rodriguez LL, Herrmann HC, et al. Echocardiographic guidance and assessment of percutaneous repair for mitral regurgitation with the Evalve MitraClip: lessons learned from EVEREST I. J Am Soc Echo. 2007;20:1131–40.

    Article  Google Scholar 

  12. Pothineni KR, Inamdar V, Miller AP, et al. Initial experience with live/real time three-dimensional transesophageal echocardiography. Echocardiography. 2007;24:1099–104.

    Article  PubMed  Google Scholar 

  13. Picard MH. Three-Dimensional Echocardiography. In: Shiota T, editor. 3D Echocardiography. London: Informa Healthcare; 2007. p. 86–111.

    Google Scholar 

  14. Biner S, Perk G, Kar S, et al. Utility of combined two-dimensional and three-dimensional transesophageal imaging for catheter-based mitral valve clip repair of mitral regurgitation. J Am Soc Echo. 2011;24:611–7.

    Article  Google Scholar 

  15. Faletra FF, Pedrazzini G, Pasotti E, Moccetti T. Side-by-side comparison of fluoroscopy, 2D and 3D TEE during percutaneous edge-to-edge mitral valve repair. JACC Cardiovas Imag. 2012;5:656–61.

    Article  Google Scholar 

  16. Webb JG, Chandavimol M, Thompson CR, et al. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation. 2006;113:842–50.

    Article  PubMed  Google Scholar 

  17. Amin Z, Forbes T, Zahn E, et al. Acute complications associated with stent placement in native and postoperative coarctation of aorta: A multi-institutional study. Circulation. 2004;110:566–566.

    Article  Google Scholar 

  18. Eng MJ, Salcedo EE, Kim M, Quaife RA, Carroll JD. Implementation of real-time three-dimensional transesophageal echocardiography for mitral balloon valvuloplasty. Catheter Cardiovasc Interv. 2013. doi:10.1002/ccd.2505219. Discussion of the approach to guidance of structural heart disease and potential procedural time and fluoroscopic radiation dose reduction that results from using RT 3D TEE guidance.

  19. Siegel RJ, Luo H, Biner S. Transcatheter valve repair/implantation. Int J Cardiovasc Imaging. 2011;27:1165–77. Discussion of the basic steps of mitral valve clip procedures.

    Article  PubMed  Google Scholar 

  20. Pua EC, Idriss SF, Wolf PD, Smith SW. Real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology: feasibility study. Ultrasonic Imag. 2007;29:182–94.

    Article  Google Scholar 

  21. Clegg SD, Chen JY, Quaife RA, Salcedo EE, Carroll JD. Integrated 3D Echo-­X-­ray image guidance for structural heart interventions. J Am Coll Cardiol. 2012;59:E326–E326.

    Article  Google Scholar 

  22. Wunderlich NC, Franke J, Ince H, Carroll JD. Integrated multimodality imaging for structural heart disease interventions. Cardiac Intervent Today. 2013;28–33. Discussion of the integration of fluoroscopy and echocardiography for imaging guidance of device procedures such as the MitraClip TM .

Download references

Compliance with Ethics Guidelines

Conflict of Interest

Robert A. Quaife has received grant support from and has been a consultant for Philips HealthCare.

Ernesto E. Salcedo has received grant support from Philips Medical.

John D. Carroll has been a consultant for, has received grant support and royalties, and has received travel/accommodations expenses covered or reimbursed from Philips HealthCare.

Human and Animal Rights and Informed Consent

This article does not contain any studies with human or animal subjects performed by any of the authors.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Robert A. Quaife.

Additional information

This article is part of the Topical Collection on Echocardiography

Rights and permissions

Reprints and permissions

About this article

Cite this article

Quaife, R.A., Salcedo, E.E. & Carroll, J.D. Procedural Guidance Using Advance Imaging Techniques for Percutaneous Edge-to-Edge Mitral Valve Repair. Curr Cardiol Rep 16, 452 (2014). https://doi.org/10.1007/s11886-013-0452-5

Download citation

  • Published:

  • DOI: https://doi.org/10.1007/s11886-013-0452-5

Keywords

Navigation