Emergency Care & Resuscitation

HeartStart MRx

Monitor/Defibrillator for emergency care

Rugged, reliable, and easy-to-use, the HeartStart MRx with the DXL 12-Lead ECG algorithm, provides industry-leading patient monitoring capabilities, exceptional diagnostic measurements, proven resuscitation therapies, and CPR guidance.

Rugged, reliable, and easy-to-use, the HeartStart MRx with the DXL 12-Lead ECG algorithm, provides industry-leading patient monitoring capabilities, exceptional diagnostic measurements, proven resuscitation therapies, and CPR guidance.

For a U.S sales representative please call 1-800-225-0230. For non-US purchasing, training, support and more click the button to contact us.
*
*
*
*
*
*
*
*
*
*
*
*
*
*

* Required fields
“When I first purchased the MRx monitors I knew I was getting a great piece of equipment. What I didn’t know is that Philips Healthcare would transition from a vendor to a partner in saving lives every day. Philips has continually provided support and knowledge that put them first in class. Their willingness to work with organizations to accomplish a task is something I will always appreciate.”

-Brian Rogers EMS Training Officer Henderson Fire Department Chief Operating Officer/Principle Community Ambulance

Features

  • Seamless wireless data transmission of 12-lead ECGs with optional Wireless Link.
  • Easy to use interface.
  • Large color screen displays 4 waveforms and numerics, or all 12 leads and numerics.
  • Flexible Event Summary allows configuration of the data you want.
  • Time Insensitive Predictive Instrument (ACI-TIPI) helps predict probability of acute ischemia.
  • Thrombolytic Predictive Instrument (TPI) helps predict patient outcome with and without thrombolytic therapy.
  • SMART Biphasic therapy for high first shock efficacy for long downtime SCA patients.
  • Quick Shock for fast time to shock.

Specifications Show all

Physical dimensions
Weight
13.2 lbs. (6 kg): base unit with 1 battery/pads and pads cable. 13 lbs. (5.9 kg) with optional 75 mm strip chart printer. Paddle tray and external standard paddles add less than 2.5 lbs. (1.1 kg). Carrying case adds 4.1 lbs. (1.86 kg). lbs/ kg
Size with external paddles
12.4" (W) x 7.7" (D) x 13.4" (H) (313 mm x 195 mm x 340 mm) "/ mm
Physical dimensions Defibrillator model HeartStart MRx (M3536A)
Size without external paddles
12.4" (W) x 7.7" (D) x 11.7" (H) (313 mm x 195 mm x 295 mm) "/ mm
Battery
Type
6.3 Ah, 14.8 V, rechargeable lithium ion Ah/V
Dimensions
6.5" (H) x 3.8" (W) x 1.6" (D) (165 mm x 95 mm x 42 mm) "/ mm
Capacity
At least 5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring. With NBP every 15 minutes on one new fully charged battery hours
Weight
1.6 lb. (0.73 kg) lb/ kg
Charge Time
Approximately 3 hours from fully depleted to 100%. 90 minutes from fully depleted to 80% hours/%
Capacity(b)
At least 3.5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring. With NBP every 15 minutes and pacing at 180 ppm at 160 mA on one new fully charged battery hours
End-tidal CO2
Range
0 to 99 mmHg mmHg
Resolution
1 mmHg (0.1 kPa) mmHg/kPa
Sample Size
50 ml per minute ml
Alarm Range(h)
Low Limit: 10 to 95 mmHg (Adult/Pediatric) mmHg
Alarm Range(i)
High Limit: 20 to 100 mmHg (Adult/Pediatric) mmHg
Power supply
Type
6.3 Ah, 14.8 V, rechargeable lithium ion Ah/V
Environmental & physical requirements
Solids/Water resistance
IP24
Operating temperature
0º - 45º C (32º - 113º F) ° C/° F
Storage temperature
-20 - 70º C (-4º - 158º F) ° C/° F
Operating humidity
0% to 95% relative %
Operating altitude
0 to 15000 ft (0 to 4500 m) ft/ m
Storage altitude
0 to 15000 ft (0 to 4500 m) ft/ m
Mechanical shock
Bump: IEC 68-2-29
Freefall: IEC 68-2-32
Operating vibration
MIL STD 810E 514.4 Category 6 Helicopter
General storage vibration
UH60 Non-Operating: IEC 68-2-6 Swept Sine Vibration and IEC 68-2-64 Random Vibration
Safety
Meets EN 60601-1, UL 2601-1/CSA C22.2 No. 601-1
Display
Dimensions
8.4’’ diagonal (128 mm x 171 mm) "/ mm
Type
TFT color LCD
Resolution
1 mmHg (0.1 kPa) mmHg/kPa
Type
TFT color LCD
Resolution
480 x 640 pixels (VGA)
Wave Viewing Time
5 seconds (ECG) seconds
Defibrillation
Waveform
Truncated Exponential Biphasic.Waveform parameters adjusted as a function of patient impedance.
Output Energy
Manual (selected): 1-10/15/20/30/50/70/100/120/150/170/200 Joules into a 50 Ohm load AED Mode (single energy output): 150 Joules into a 50 ohm load. Joules/Ohm
Charge Time
Less than 5 seconds to 200 Joules with a new/ fully charged lithium ion battery at 25º C
Shock Delivery
Via multifunction defib electrode pads or paddles
Shock-to-Shock Cycle Time
Typically less than 20 seconds
Minimum Patient Impedance Range
15 Ohm (internal defibrillation); 25 Ohm (external defibrillation) Ohm
Maximum Patient Impedance Range
180 Ohm
AED Mode
Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines
Noninvasive Blood Pressure
Pressure Range(a)
Systolic: 40 to 260 mmHg
Pressure Range(b)
Diastolic: 20 to 200 mmHg
Initial Pressure
Adult: 160 mmHg and Pediatric: 120 mmHg
Maximum Pressure
280 mmHg
Alarm Range(d)
Systolic high limit: 30 - 270 (Adult) and 35 - 180 (Pediatric)
Alarm Range(e)
Systolic low limit: 30 - 265 (Adult) and 30 - 175 (Pediatric)
Alarm Range(f)
Diastolic high limit: 18 - 240 (Adult) and 18 - 150 (Pediatric)
Alarm Range(g)
Diastolic low limit: 10 - 240 (Adult) and 10 - 145 (Pediatric)
Strip Chart Recorder
Recorder(a)
Standard: 50 mm (paper width) thermal array printer mm
Recorder(b)
Optional: 75 mm (paper width) thermal array printer mm
Continuous ECG Strip
Prints primary ECG lead with event annotations and measurements in real-time or with 10-second delay
Auto Printing
Recorder can be configured to print marked events/charge/ shock and alarms
Reports
Event Summary, 12-Lead/Operational Check/ Configuration/Status Log and Device Information
Paper Size
1.97” (50 mm) W by 100 ft. (30 m) L and 2.95” (75 mm) W by 100 ft. (30 m) L "/ft/mm/m
Data storage
Internal
12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports
Data Card
12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports on a CompactFlash memory card
ECG and arrhythmia monitoring
Input
Up to 4 ECG waves displayed and up to 3 ECG waves print simultaneously.
Leads
Lead I, II, or III obtained through 3-lead ECG cable and separate monitoring electrodes. With 5-lead cable, obtain leads I/II/III/aVR/aVL/ aVF or V. Pads ECG obtained through 2 multifunction defibrillation electrode pads.
Lead Fault
‘Lead Off ’ message and dashed line displayed if an electrode or lead wire becomes disconnected.
Pads Fault
Dashed line displayed if a pad becomes disconnected.
Heart Rate Display
Digital readout on display 15 to 300 bpm with accuracy ±10% bpm/%
Heart Rate/Arrhythmia Alarms
HR/Asystole/VFIB/VTACH/VTACH/extreme tachycardia/extreme bradycardia/PVC rate.
ECG Size
2.5/5/10/20/40 mm/mV autogain mm/mV
SpO2 pulse oximetry
Range
0 to 100 %
Resolution
0.01 %
Alarm Range(a)
Low Limit: 50 to 99% (Adult/Pediatric) %
Alarm Range(b)
High Limit: 51 to 100% (Adult/Pediatric) %
Alarm Delay
10 seconds
12-Lead ECG
Input
12-Lead cable: leads I/II/III/aVR/aVL/ aVF and V/C1-V/C6
Display View
All 12-lead ECG waves display simultaneously
Strip Recorder
All 12-leads print on the strip chart printer in 3x4 format
Transmission
CompactFlash data card; Bluetooth® dial-up Internet connection, Bluetooth® FTP
CPR feedback and measurement
Compression Depth
Target: -1.50 to -2.00" (-38 to -51 mm) "/ mm
Compression Rate
Target: 90 to 120 cpm cpm
Ventilation Volume
Graphic indicator: empty/one-third full/two-thirds full/full
Ventilation Rate(a)
Target for breaths delivered before 60 seconds since last compression: 6 to 16 vpm seconds/vpm
Ventilation Rate(b)
Target for breaths delivered beyond 60 seconds since last compression: 9 to 16 vpm seconds/vpm
Noninvasive pacing
Current Pulse Amplitude
10 mA to 160 mA (5 mA resolution); accuracy 10 mA to 50 mA ± 5 mA, 50 mA - 160 m A ± 10% mA
Pulse Width
40 ms with ± 10% accuracy ms/%
Rate
30 ppm to 180 ppm (10 ppm increments); accuracy ± 1.5% ppm
Modes
Demand or Fixed Rate
Refractory Period
340 msec (30 to 80 ppm); 240 msec (90 to 180 ppm) msec/ppm

Supplies list

 

Supplies for your Philips EMS equipment are as rugged, reliable and affordable as the devices themselves. Below, find the key supplies you need for your HeartStartMRx monitor/defibrillator. Some are available on our eStore and all may be ordered by phone.

 

View a complete list of supplies for our EMS products

 

Product number

 

Supply name

 

Description

 

Category

 

989803176161

 

Most popular

5-Lead Shielded Limb Snap

 

Rugged lead sets include labels that can be seen in low-light environments

 

Leads

 

989803176171

 

Most popular

5-Lead Shielded Chest Snap

 

Rugged lead sets include labels that can be seen in low-light environments

 

Leads

 

989803166021

 

Most popular

Adult/Child Preconnect Pads

 

Pads

 

M4737A

 

Most popular

MRx Display Cover

 

Accessories

 

M3716A

 

Adult/Child Radiolucent Pads

 

Pads

 

M3713A

 

Adult/Child Plus

 

Pads

 

M3717A

 

Infant Plus Pads

 

Pads

 

M3538A

 

Lithium Ion Battery Module

 

Power

 

M5529A

 

DC Power Module

 

Power

 

40401B

 

Traditional Reusable NBP Cuff

 

Pediatric, 1 cuff

 

NIBP

 

M3725A

 

HeartStart 50 ohm

Test Load

 

Test Load

 

 

M1920A

 

Filter Line Set

 

Adult/Pediatric (25 sets/case)

 

EtCO2

 

989803158661

 

Replacement Pads/CPR

Meter Cable

 

Cables

 

M1663A

 

10-Lead ECG Patient Trunk Cable, 12-pin Accessories

 

Cables

Support