SureSigns VS4
Vital signs monitor
  • Product detail photograph
  • Product in use photograph
  • Product with accessory photograph

SureSigns VS4

Vital signs monitor
Expand vital signs monitoring with Philips SureSigns VS4. Respond to changing patient conditions by choosing between frequent vitals and spot check mode. Prompt urgent action with QuickAlerts and simplify workflow with QuickCapture and QuickCheck tools.

Features
Works with your existing network
Philips SureSigns VS4 provides automated delivery of vital signs data from bedside monitors to the hospital's electronic health record (EHR), helping clinicians chart vitals into a patient's record at the point-of-care.
QuickCapture to customize up to 40 entries
Customize up to 40 observation and assessment entries for fast recall and reuse
QuickCheck for fast validation
Quickly validate patient information at the point of care with QuickCheck. It allows care giver and patient record authentication at the bedside. The patient record can be reviewed before export to EHR.


Specifications
  • SureSigns VS4
    Dimensions
    26 (10.2) x 22 (8.6) x 14.5 (5.7) Cm/in.
    Weight
    3.1 (6.9) – exluding optional recorder Kg/lb
    Screen
    8.4 inch SVGA TFT-AM LCD display, 800 active pixels/line; resolution: 600 active lines/frame; viewing angle ±60 degrees
    Stepwise deflation pressure (Adult)
    Diastolic: 10-245 (1.3-32.7); Systolic: 30-270 (4.0-36.0); MAP: 20-255 (2.7-34.0) mmHg/kPa
    Stepwise deflation pressure (Pediatric)
    Systolic: 30-180 (4.0-24.0); Diastolic: 10-150 (1.3-20.0); MAP: 20-160 (2.7-21.3) mmHg/kPa
    Stepwise deflation pressure (Neonatal)
    Systolic: 30-130 (4.0-17.0); Diastolic: 10-100 (1.3-13.3); MAP: 20-120 (2.7-16.0) mmHg/kPa
    NBP measurement accuracy
    Maximum standard deviation: 8 mmHg; Maximum mean error: ±5mmHg
    Subsequent cuff inflation (in NBP interval mode only)
    The subsequent inflation pressure is determined automatically, depending on the previous measurement and patient type
    SpO2 measurement range
    0-100%; pulse rate measurement range 30-300 pbm. Accuracy depends on sensor
    SpO2
    Meets EN ISO 9919 standard
    Welch Allyn* Predictive Temperature
    Probe Sites: Oral, rectal, axillary; Range 26.7-43.3°C (80-110°F); Accuracy ±0.1°C (±0.2°F) in monitoring mode
    Covidien Tympanic Temperature
    • Range: 33°C-42°C (91.4°F-107.6°F)
    • Accuracy (overall range): ±0.2°C (±0.4°F)
    • Measurement response time: ≤2
    Covidien** Tympanic Temperature
    Equivalency modes: ear (no adjustment), oral (adjusted from ear), core (adjusted from ear), rectal (adjusted from ear)
    Battery
    Lithium ion: 10.8-11.1V (with a “202” form factor)
    Data Output
    HL7 format, via Ethernet port; serial data
    Patient type
    Adult, pediatric, neonatal

Documentation

Case Study: Philips SureSigns Vital S4 with IntelliBridge Enterprise
PDF|369.55 KB
Disclaimer
*Welch Allyn® & SureTemp® are registered trademarks of Welch Allyn.
**Covidien is a U.S. and international trademark or registered trademark of Covidien AG.
Microstream and Covidien are trademarks of Covidien companies