Tempus Pro Rugged, lightweight advanced AED monitor

Tempus Pro

Rugged, lightweight advanced AED monitor

Find similar products

The Tempus Pro places the needs of the prehospital care professional at the heart of its design. Ground-breaking in functionality, it is light enough to carry and small enough to hold in one hand. Rugged, yet highly intuitive to operate, it can easily be deployed in a wide range of clinical scenarios, with advanced capabilities to allow clear, documented decision-making.

Features
Flexible and scalable to suit you

Unique, scalable platform

The functionality of the Tempus Pro system can be extended and upgraded when you need it to be. Add video laryngoscopy, ultrasound, defibrillation and telemedicine to further advance capabilities. And access feature, software and system updates, and configuration tools to evolve your system in line with your requirements, budgets and protocols.
Extensive data capture ability

Capture, connect and decide

The Tempus Pro allows you to capture as much or as little data as you need. The on-screen smart patient care record can be augmented via the touchscreen, while you can choose how much data to collect and exactly what, when, where and how to share it. All data is encrypted and shared via authenticated, highly secure channels.
Easy to deploy, even in hostile environments

Practical design and operation

The Tempus Pro features a 6.5" daylight-readable color display with high contrast mode, a glove-friendly touchscreen interface and multiple user-selectable display options. It is also night-vision compatible and features an integrated tactical switch for hostile environments.
Easy to carry on your shoulder

Small, light, robust

The Tempus Pro is designed and built to meet the needs of prehospital care professionals. Weighing only 2.9 kg (6.4 lb) with a slender profile, the monitor allows you to flexibly carry all you need with you to the scene. The Tempus Pro is also highly durable – with an IP66 rating underlining its suitability for deployment in the most challenging environments.
  • Flexible and scalable to suit you
  • Extensive data capture ability
  • Easy to deploy, even in hostile environments
  • Easy to carry on your shoulder
See all features
Flexible and scalable to suit you

Unique, scalable platform

The functionality of the Tempus Pro system can be extended and upgraded when you need it to be. Add video laryngoscopy, ultrasound, defibrillation and telemedicine to further advance capabilities. And access feature, software and system updates, and configuration tools to evolve your system in line with your requirements, budgets and protocols.
Extensive data capture ability

Capture, connect and decide

The Tempus Pro allows you to capture as much or as little data as you need. The on-screen smart patient care record can be augmented via the touchscreen, while you can choose how much data to collect and exactly what, when, where and how to share it. All data is encrypted and shared via authenticated, highly secure channels.
Easy to deploy, even in hostile environments

Practical design and operation

The Tempus Pro features a 6.5" daylight-readable color display with high contrast mode, a glove-friendly touchscreen interface and multiple user-selectable display options. It is also night-vision compatible and features an integrated tactical switch for hostile environments.
Easy to carry on your shoulder

Small, light, robust

The Tempus Pro is designed and built to meet the needs of prehospital care professionals. Weighing only 2.9 kg (6.4 lb) with a slender profile, the monitor allows you to flexibly carry all you need with you to the scene. The Tempus Pro is also highly durable – with an IP66 rating underlining its suitability for deployment in the most challenging environments.

Specifications

Physical dimensions
Physical dimensions
Display
  • Color 165 mm (6.5”) 640x480 pixels, 130 klux daylight readable display
Standalone weight
  • 2.9 kg (6.4 Ib) with battery and RapidPak clip only (with printer 3.2 kg (7 Ib))
Standalone size
  • 263 x 216 x 100 mm (10.3" x 8.5" x 3.9")
Pulse oximetry - Total hemoglobin (SpHb® g/dL)²
Pulse oximetry - Total hemoglobin (SpHb® g/dL)²
Accuracy (adult/ped/infant)
  • 8 - 17 g/dL ± 1 g/dL
Range
  • 0-25 g/dL
Integral digital camera
Integral digital camera
Video streaming
  • H264 algorithm (bandwidth dependent)
Resolution
  • 3.2 megapixels
Images
  • Included in patient record
Ultrasound and video laryngoscopy²
Ultrasound and video laryngoscopy²
Interson (optional)
  • General purpose, 3.5 MHz and line placement 7.5 MHz
Karl Storz C-Mac (optional)
  • Video laryngoscope imager and single use blades
Pulse oximetry - Total oxygen content (SpOC®)²
Pulse oximetry - Total oxygen content (SpOC®)²
Range
  • 0-35 ml of O2/dL
Impedance respiration
Impedance respiration
Accuracy
  • ±2 RPM or ±2% whichever is greater
Range
  • 3-150 RPM
Anesthetic gas monitoring²
Anesthetic gas monitoring²
Display of AA gas vitals
  • Optional Masimo ISA OR+ anesthestic gas module
Contact temperature
Contact temperature
Resolution
  • ±0.1°C / ±0.2 °F; accuracy: ±0.1 ºC
Measurement range
  • 20–45°C (68–113°F)
Compatability³
  • 2 channel YSI 400 series
Invasive pressure²
Invasive pressure²
Range
  • -99-310 mmHg
Expansion
  • Up to 4 channels via USB module²
2 channels
  • 5 μV/V/mmHg, Response: 0–20 Hz (-3 dB)
Filters
  • 50-60 Hz notch
Noninvasive blood pressure
Noninvasive blood pressure
Neonate range
  • 20-130 mmHg
Cuffs
  • Neonate disposable 1-5, infant, child, adult, large adult, thigh, cuff kit
Accuracy
  • ±3 mmHg or ±2% (whichever is greater)
Pediatric range
  • 20-230 mm/Hg
Adult range
  • 20-260 mmHg
ECG monitoring
ECG monitoring
Frequency response
  • 0.05-175 Hz , ±3dB
Accuracy
  • ±3%, DC offset, ±300 mV dc
3,4,5 and 12-lead monitoring
  • via standard snap-on electrode
Common mode rejection
  • 95 dB minimum, additional filters include mains, muscle, and low and high pass
Acquisition and interpretation
  • 12-lead acquisition² and 12-lead interpretation
QT segment measurement
  • with alarms²
Acquisition sample rate
  • 500 Hz
Arrhythmia monitoring/alarms
  • Arrhythmia monitoring/alarms
Heart rate range
  • 30-300 bpm
ST elevation
  • ST elevation
Microstream etCO₂*
Microstream etCO₂*
Range
  • 0-150 mm/Hg
Flow rate (measured by volume)
  • 50 (42.5 ≤ flow ≤ 65) ml/min
Accuracy
  • 0–38 mmHg: ±2 mmHg; 39–150 mmHg: ±5% of reading; +0.08% per 1 mmHg over 38 mmHg
Capnometry²
Capnometry²
Respiration rate range
  • 1-149 bpm
Respiration rate accuracy
  • 0–70 BPM ±1 BPM 71–121 BPM ±2 BPM 122–149 BPM ±3 BPM
Pulse oximetry - SpO₂
Pulse oximetry - SpO₂
Sensor
  • Comfortable, waterproof, soft-tip
Response
  • <lt/>1 second delay
Range
  • 1-100 %
Pleth Variability Index (PVI®)²
  • Pleth Variability Index (PVi)²
Perfusion index
  • 0,02-20 %
Technology
  • Masimo rainbow SET®
Accuracy (neonate)
  • Motion, no motion and low perfusion ±3 digits 70–100%
Accuracy (adult/ped)
  • No motion or low perfusion ±2 digits 70–100%, motion ±3 digits 70–100%
Pulse oximetry - Carboxyhaemoglobin (SpCO®)²
Pulse oximetry - Carboxyhaemoglobin (SpCO®)²
Accuracy (adult/ped/infant)
  • 1-40 %, ± 3%
Range
  • 0-99.9 %
Pulse oximetry - Methemoglobin (SpMet®)²
Pulse oximetry - Methemoglobin (SpMet®)²
Accuracy (all ages)
  • 1-15 %, ± 1%
Range
  • 0-99.9 %
Pulse rate
Pulse rate
Range
  • 25-239 BPM
Accuracy (all ages)
  • No motion ≤3 digits, motion ≤5 digits
Operating time
Operating time
Up to 14 hours
  • With battery saving mode activated⁴
11.5 hours
  • Display brightness at 30%, ECG, SpO₂, EtCo₂, temp x2 and NBP every 15 minutes
10.75 hours
  • Display brightness at 60%, ECG, SpO₂, EtCo₂, temp x2 and NBP every 15 minutes
Physical dimensions
Physical dimensions
Display
  • Color 165 mm (6.5”) 640x480 pixels, 130 klux daylight readable display
Standalone weight
  • 2.9 kg (6.4 Ib) with battery and RapidPak clip only (with printer 3.2 kg (7 Ib))
Pulse oximetry - Total hemoglobin (SpHb® g/dL)²
Pulse oximetry - Total hemoglobin (SpHb® g/dL)²
Accuracy (adult/ped/infant)
  • 8 - 17 g/dL ± 1 g/dL
Range
  • 0-25 g/dL
See all specifications
Physical dimensions
Physical dimensions
Display
  • Color 165 mm (6.5”) 640x480 pixels, 130 klux daylight readable display
Standalone weight
  • 2.9 kg (6.4 Ib) with battery and RapidPak clip only (with printer 3.2 kg (7 Ib))
Standalone size
  • 263 x 216 x 100 mm (10.3" x 8.5" x 3.9")
Pulse oximetry - Total hemoglobin (SpHb® g/dL)²
Pulse oximetry - Total hemoglobin (SpHb® g/dL)²
Accuracy (adult/ped/infant)
  • 8 - 17 g/dL ± 1 g/dL
Range
  • 0-25 g/dL
Integral digital camera
Integral digital camera
Video streaming
  • H264 algorithm (bandwidth dependent)
Resolution
  • 3.2 megapixels
Images
  • Included in patient record
Ultrasound and video laryngoscopy²
Ultrasound and video laryngoscopy²
Interson (optional)
  • General purpose, 3.5 MHz and line placement 7.5 MHz
Karl Storz C-Mac (optional)
  • Video laryngoscope imager and single use blades
Pulse oximetry - Total oxygen content (SpOC®)²
Pulse oximetry - Total oxygen content (SpOC®)²
Range
  • 0-35 ml of O2/dL
Impedance respiration
Impedance respiration
Accuracy
  • ±2 RPM or ±2% whichever is greater
Range
  • 3-150 RPM
Anesthetic gas monitoring²
Anesthetic gas monitoring²
Display of AA gas vitals
  • Optional Masimo ISA OR+ anesthestic gas module
Contact temperature
Contact temperature
Resolution
  • ±0.1°C / ±0.2 °F; accuracy: ±0.1 ºC
Measurement range
  • 20–45°C (68–113°F)
Compatability³
  • 2 channel YSI 400 series
Invasive pressure²
Invasive pressure²
Range
  • -99-310 mmHg
Expansion
  • Up to 4 channels via USB module²
2 channels
  • 5 μV/V/mmHg, Response: 0–20 Hz (-3 dB)
Filters
  • 50-60 Hz notch
Noninvasive blood pressure
Noninvasive blood pressure
Neonate range
  • 20-130 mmHg
Cuffs
  • Neonate disposable 1-5, infant, child, adult, large adult, thigh, cuff kit
Accuracy
  • ±3 mmHg or ±2% (whichever is greater)
Pediatric range
  • 20-230 mm/Hg
Adult range
  • 20-260 mmHg
ECG monitoring
ECG monitoring
Frequency response
  • 0.05-175 Hz , ±3dB
Accuracy
  • ±3%, DC offset, ±300 mV dc
3,4,5 and 12-lead monitoring
  • via standard snap-on electrode
Common mode rejection
  • 95 dB minimum, additional filters include mains, muscle, and low and high pass
Acquisition and interpretation
  • 12-lead acquisition² and 12-lead interpretation
QT segment measurement
  • with alarms²
Acquisition sample rate
  • 500 Hz
Arrhythmia monitoring/alarms
  • Arrhythmia monitoring/alarms
Heart rate range
  • 30-300 bpm
ST elevation
  • ST elevation
Microstream etCO₂*
Microstream etCO₂*
Range
  • 0-150 mm/Hg
Flow rate (measured by volume)
  • 50 (42.5 ≤ flow ≤ 65) ml/min
Accuracy
  • 0–38 mmHg: ±2 mmHg; 39–150 mmHg: ±5% of reading; +0.08% per 1 mmHg over 38 mmHg
Capnometry²
Capnometry²
Respiration rate range
  • 1-149 bpm
Respiration rate accuracy
  • 0–70 BPM ±1 BPM 71–121 BPM ±2 BPM 122–149 BPM ±3 BPM
Pulse oximetry - SpO₂
Pulse oximetry - SpO₂
Sensor
  • Comfortable, waterproof, soft-tip
Response
  • <lt/>1 second delay
Range
  • 1-100 %
Pleth Variability Index (PVI®)²
  • Pleth Variability Index (PVi)²
Perfusion index
  • 0,02-20 %
Technology
  • Masimo rainbow SET®
Accuracy (neonate)
  • Motion, no motion and low perfusion ±3 digits 70–100%
Accuracy (adult/ped)
  • No motion or low perfusion ±2 digits 70–100%, motion ±3 digits 70–100%
Pulse oximetry - Carboxyhaemoglobin (SpCO®)²
Pulse oximetry - Carboxyhaemoglobin (SpCO®)²
Accuracy (adult/ped/infant)
  • 1-40 %, ± 3%
Range
  • 0-99.9 %
Pulse oximetry - Methemoglobin (SpMet®)²
Pulse oximetry - Methemoglobin (SpMet®)²
Accuracy (all ages)
  • 1-15 %, ± 1%
Range
  • 0-99.9 %
Pulse rate
Pulse rate
Range
  • 25-239 BPM
Accuracy (all ages)
  • No motion ≤3 digits, motion ≤5 digits
Operating time
Operating time
Up to 14 hours
  • With battery saving mode activated⁴
11.5 hours
  • Display brightness at 30%, ECG, SpO₂, EtCo₂, temp x2 and NBP every 15 minutes
10.75 hours
  • Display brightness at 60%, ECG, SpO₂, EtCo₂, temp x2 and NBP every 15 minutes
  • ¹ Tempus Pro standalone weight: 6.4 lb (2.9 kg) nominal including battery, excluding IP module, accessories and printer.
  • ² Optional, additional feature.
  • ³ One channel fitted as standard, second channel is optional.
  • ⁴ Display active 50% of the time.
  • Masimo®, Masimo rainbow SET®, PVi®, SpHb®, SpMet®, SpCO® and SpOC® are the property of Masimo Inc.
  • Oridion and Microstream are trademarks of Medtronic.
  • C-MAC is the property of Karl Storz.
  • * Uses Oridion Microstream technology

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.