AC611 High Flow Nasal Cannula, Large

AC611

High Flow Nasal Cannula, Large

Find similar products

The Philips High Flow Nasal Cannula AC611 provides comfortable, stable oxygen delivery, and employs the same circuit as our NIV masks to help you control costs and enhance workflow. It is compatible with our V60 Plus ventilator to support the use of noninvasive ventilation (NIV) and high flow therapy (HFT) with a single system.

Features
Comfortable therapy
Available in a range of sizes

Available in a range of sizes

The High Flow Nasal Cannula AC611 eases the transition from NIV to HFT and is available in a range of sizes to fit most patients. Rated as most comfortable in head-to-head testing,1 it adds versatility to your inventory.
Inventory versatility
Uses the same circuit as NIV masks

Uses the same circuit as NIV masks

The AC611 can be used with our V60 Plus ventilator and stand-alone high flow therapy systems, adding versatility to your cannula supplies inventory. It uses the same circuit as our NIV masks, making it easy to switch therapies.
Stable and comfortable
Features keep the cannula in place

Features keep the cannula in place

The AC611’s adjustable headgear keeps the cannula in place, even when the patient changes position. The gown clip reduces unwanted cannula movement, so patients consistently receive the intended flow.
  • Comfortable therapy
  • Inventory versatility
  • Stable and comfortable
See all features
Comfortable therapy
Available in a range of sizes

Available in a range of sizes

The High Flow Nasal Cannula AC611 eases the transition from NIV to HFT and is available in a range of sizes to fit most patients. Rated as most comfortable in head-to-head testing,1 it adds versatility to your inventory.
Inventory versatility
Uses the same circuit as NIV masks

Uses the same circuit as NIV masks

The AC611 can be used with our V60 Plus ventilator and stand-alone high flow therapy systems, adding versatility to your cannula supplies inventory. It uses the same circuit as our NIV masks, making it easy to switch therapies.
Stable and comfortable
Features keep the cannula in place

Features keep the cannula in place

The AC611’s adjustable headgear keeps the cannula in place, even when the patient changes position. The gown clip reduces unwanted cannula movement, so patients consistently receive the intended flow.

Specifications

Disposal
Disposal
Dispose of in accordance with local regulations
  • Yes
Flow range
Flow range
Medium
  • ≤ 80 l/min
Large
  • ≤ 80 l/min
Small
  • ≤ 70 l/min
Storage conditions
Storage conditions
Temperature
  • -20 – 60°C (-4 – 140°F)
Relative humidity
  • 15 – 95% (non-condensing)
Disposal
Disposal
Dispose of in accordance with local regulations
  • Yes
Flow range
Flow range
Medium
  • ≤ 80 l/min
Large
  • ≤ 80 l/min
See all specifications
Disposal
Disposal
Dispose of in accordance with local regulations
  • Yes
Flow range
Flow range
Medium
  • ≤ 80 l/min
Large
  • ≤ 80 l/min
Small
  • ≤ 70 l/min
Storage conditions
Storage conditions
Temperature
  • -20 – 60°C (-4 – 140°F)
Relative humidity
  • 15 – 95% (non-condensing)
  • 1. Philips High Flow Cannula therapy prototype testing. Conducted by ResearchWorks. 2016.
  • The AC611 High Flow Nasal Cannula is being provided for use in accordance with FDA’s guidance, Enforcement Policy for Ventilators and Accessories and Other Respiratory Devices During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency, Section IV Policy for Modifications to FDA-Cleared Devices, issued March 2020.

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.