AngioSculpt RX PTCA scoring balloon catheter significantly alters the landscape for treating CAD, offering the advanced performance that only an innovative clinical solution can provide. The AngioSculpt RX PTCA scoring balloon catheter is the only specialty scoring device indicated for ISR and complex type-C lesions.

Specifications
  • Model number 2200-2006
    Balloon diameter
    2 mm
    Balloon length
    6 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-2010
    Balloon diameter
    2 mm
    Balloon length
    10 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-2015
    Balloon diameter
    2 mm
    Balloon length
    15 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-2506
    Balloon diameter
    2.5 mm
    Balloon length
    6 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-2510
    Balloon diameter
    2.5 mm
    Balloon length
    10 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-2515
    Balloon diameter
    2.5 mm
    Balloon length
    15 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014in
    Guide catheter compatibility
    6F
  • Model number 2200-3006
    Balloon diameter
    3 mm
    Balloon length
    6 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-3010
    Balloon diameter
    3 mm
    Balloon length
    10 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-3015
    Balloon diameter
    3 mm
    Balloon length
    15 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-3506
    Balloon diameter
    3.5 mm
    Balloon length
    6 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-3510
    Balloon diameter
    3.5 mm
    Balloon length
    10 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F
  • Model number 2200-3515
    Balloon diameter
    3.5 mm
    Balloon length
    15 mm
    Catheter length
    137 cm
    Guidewire compatibility
    0.014 in
    Guide catheter compatibility
    6F


Documentation

Product brochure
PDF|3.23 MB
Disclaimer
1. Mooney M, Teirstein P, Moses J et al. Final results from the U.S. multi-center trial of the AngioSculpt Scoring Balloon Catheter for the treatment of complex coronary artery lesions. Am J Cardiol. 2006;98(8 suppl):121M
2. AngioSculpt Test Plan ST-1197 (2008), on file at AngioScore, Inc.
3. Fonseca A, Costa JR, Abizaid A, et al. Intravascular ultrasound assessment of the novel AngioSculpt Scoring Balloon Catheter for the treatment of complex coronary lesions. J Invasive Cardiol. 2008;20:21-27.
AngioSculpt PTCA important safety information
The AngioSculpt scoring balloon catheter is indicated for use in the treatment of hemodynamically significant coronary artery stenosis, including in-stent restenosis and complex type C lesions, for the purpose of improving myocardial perfusion.
The AngioSculpt catheter should not be used for coronary artery lesions unsuitable for treatment by percutaneous revascularization, and coronary artery spasm in the absence of a significant stenosis.
Possible adverse effects include, but are not limited to: death; heart attack (acute myocardial infarction); total occlusion of the treated artery; coronary artery dissection, perforation, rupture, or injury; pericardial tamponade; no/slow reflow of treated vessel; emergency coronary artery bypass (CABG); emergency percutaneous coronary intervention; CVA/stroke; pseudoaneurysm; restenosis of the dilated vessel; unstable chest pain (angina); thromboembolism or retained device components; irregular heart rhythm (arrhythmias, including life-threatening ventricular arrhythmias); severe low (hypotension)/high (hypertension) blood pressure; coronary artery spasm; hemorrhage or hematoma; need for blood transfusion; surgical repair or vascular access site; creation of a pathway for blood flow between the artery and the vein in the groin (arteriovenous fistula); drug reactions, allergic reactions to x-ray dye (contrast medium); and infection.
This information is not intended to replace a discussion with your healthcare provider on the benefits and risks of this procedure to you.
Caution: Federal law restricts the devices referenced on this site to sale by or on the order of a physician.
Product availability is subject to country regulatory clearance. Please contact your local sales representative to check the availability in your country.
AngioSculpt RX PTCA is distributed by Biotronik in Australia and New Zealand.
Always read the label and follow the directions for use.
Philips medical devices should only be used by physicians and teams trained in interventional techniques, including training in the use of this device.
Philips reserves the right to change product specifications without prior notification.
©2025 Koniklijke Philips N.V. All rights reserved. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.