Turbo-Elite
Laser atherectomy catheter
  • Philips Peripheral Laser Atherectomy Catheter Animation
  • The Turbo-Elite family of catheters can treat lesions both above and below the knee ablating material at the molecular level and modifying plaque for a more consistent outcome.¹⁻⁴
  • Turbo-Elite laser atherectomy catheter animation
  • With one of the largest size ranges of any atherectomy catheter, Turbo-Elite can fit into standard procedural practice working with the physician's preferred wire and introducer sheath.
  • Compatible in all types of morphologies from calcium to ISR* and is the only atherectomy device with zero contraindications.¹⁻⁴
  • Standard product photograph

Turbo-Elite

Laser atherectomy catheter
Turbo-Elite laser atherectomy catheter captures the power of ultraviolet light to provide a versatile and reliable tool for treating multiple lesion morphologies within PAD lesions. Utilizing laser's unique mechanism of action, Turbo-Elite is capable of powering through the most challenging restenoses and occlusions.

Clinical image gallery

  • Turbo-Elite: pre & post procedure
    Turbo-Elite: pre & post procedure
Features
Versatile performance
Turbo-Elite uniformly and reliably helps treat a variety of morphologies and locations with a single catheter.
Strong clinical support
Turbo-Elite has a proven record of safety and effectiveness with results that consistently demonstrate an ability to save limbs and treat lesions both above and below the knee.¹⁻⁴
Cost-effective solution
Through a single device that can both cross and debulk a lesion, Turbo-Elite provides you with clinical efficacy and reliability at a lower cost per case than other technologies.


Specifications
  • Model number 410-152 peripheral over-the-wire catheter
    Catheter diameter
    0.9 mm
    Vessel diameter
    ≥1.4 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    4F
    Max tip outer diameter
    0.038”
    Max shaft outer diameter
    0.047”
    Working length
    150 cm
    Fluence
    30-80 mJ/mm²
    Repetition
    25-80 Hz
  • Model number 414-151 peripheral over-the-wire catheter
    Catheter diameter
    1.4 mm
    Vessel diameter
    ≥2.1 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    5F
    Max tip outer diameter
    0.055”
    Max shaft outer diameter
    0.056”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 417-152 peripheral over-the-wire catheter
    Catheter diameter
    1.7 mm
    Vessel diameter
    ≥2.6 mm
    Max guidewire compatibility
    0.018”
    Sheath compatibility
    5F
    Max tip outer diameter
    0.068”
    Max shaft outer diameter
    0.069”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 420-006 peripheral over-the-wire catheter
    Catheter diameter
    2 mm
    Vessel diameter
    ≥3.0 mm
    Max guidewire compatibility
    0.018”
    Sheath compatibility
    6F
    Max tip outer diameter
    0.080”
    Max shaft outer diameter
    0.081”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 423-001 peripheral over-the-wire catheter
    Catheter diameter
    2.3 mm
    Vessel diameter
    ≥3.5 mm
    Max guidewire compatibility
    0.018”
    Sheath compatibility
    7F
    Max tip outer diameter
    0.091”
    Max shaft outer diameter
    0.091”
    Working length
    120 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 425-011 peripheral over-the-wire catheter
    Catheter diameter
    2.5 mm
    Vessel diameter
    ≥3.8 mm
    Max guidewire compatibility
    0.018”
    Sheath compatibility
    8F
    Max tip outer diameter
    0.101”
    Max shaft outer diameter
    0.102”
    Working length
    110 cm
    Fluence
    30-45 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 423-135 peripheral over-the-wire catheter
    Catheter diameter
    2.3 mm
    Vessel diameter
    ≥3.5 mm
    Max guidewire compatibility
    0.035”
    Sheath compatibility
    7F
    Max tip outer diameter
    0.091”
    Max shaft outer diameter
    0.091”
    Working length
    125 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 425-135 peripheral over-the-wire catheter
    Catheter diameter
    2.5 mm
    Vessel diameter
    ≥3.8 mm
    Max guidewire compatibility
    0.035”
    Sheath compatibility
    8F
    Max tip outer diameter
    0.101”
    Max shaft outer diameter
    0.102”
    Working length
    112 cm
    Fluence
    30-60mJ/mm²
    Repetition rate
    25-80Hz
  • Model number 410-154 peripheral rapid exchange catheter
    Catheter diameter
    0.9 mm
    Vessel diameter
    ≥1.4 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    4F
    Max tip outer diameter
    0.038”
    Max shaft outer diameter
    0.049”
    Working length
    150 cm
    Fluence
    30-80 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 414-159 peripheral rapid exchange catheter
    Catheter diameter
    1.4 mm
    Vessel diameter
    ≥2.1 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    5F
    Max tip outer diameter
    0.057”
    Max shaft outer diameter
    0.062”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 417-156 peripheral rapid exchange catheter
    Catheter diameter
    1.7 mm
    Vessel diameter
    ≥2.6 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    6F
    Max tip outer diameter
    0.069” in
    Max shaft outer diameter
    0.072”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz
  • Model number 420-159 peripheral rapid exchange catheter
    Catheter diameter
    2 mm
    Vessel diameter
    ≥3.0 mm
    Max guidewire compatibility
    0.014”
    Sheath compatibility
    7F
    Max tip outer diameter
    0.080”
    Max shaft outer diameter
    0.084”
    Working length
    150 cm
    Fluence
    30-60 mJ/mm²
    Repetition rate
    25-80 Hz


Documentation

LACI clinical abstract
PDF|132.21 KB

Related products

  • CVX-300 Excimer laser system
    The only PMA approved excimer laser system and disposable catheters for the treatment of coronary arterial disease. CVX-300 is also indicated for use in the treatment of peripheral arterial disease. Photoablation is the use of light to break down, vaporize and remove matter. The CVX-300 excimer laser system facilitates photoablation via a variety of Philips laser catheters to remove binding arterial plaques.
  • Philips Laser System — Nexcimer Laser system for coronary and peripheral atherectomy and lead management
    Philips Laser System —Nexcimer— photoablates a wide spectrum of morphologies. Philips laser catheters are indicated in many vessel types and is the only laser system available for lead removal. Powered by a common 100-240V electrical outlet, the system warms up in less than 30 seconds for an easy and fast set-up.
  • Phoenix Atherectomy System Rotational atherectomy system
    The Phoenix atherectomy system combines the benefits of existing atherectomy systems to deliver a unique atherectomy option to help physicians tailor the treatment approach for each patient.¹ It cuts, captures, and clears diseased tissue with one insertion. Phoenix treats a broad range of tissue types, from soft plaque to calcified arteries, and can be used for lesions above and below the knee.²,³
Disclaimer
1. Dippel et al. Excimer laser recanalization of femoropopliteal lesions and 1-year patency: results of the CELLO registry. J Endovasc Ther. 2009 Dec;16(6):665-75.
2. Zeller et al. J Endovasc Ther. Photoablation using the turbo-booster and excimer laser for in-stent restenosis treatment: twelve-month results from the PATENT study. J Endovasc Ther. 2014 Feb;21(1):52-60
3. Dippel et al. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis). JACC Cardiovasc Interv. 2015 Jan;8(1 Pt A):92-101
4. Laird et al.  Limb Salvage Following Laser-Assisted Angioplasty for Critical Limb Ischemia: Results of the LACI Multi­center Trial. J Endovasc Ther. 2006 Feb;13(1):1-11
*When used with Turbo-Tandem and PTA
**Images courtesy of Dr. Devendra Amin
Product availability is subject to country regulatory clearance. Please contact your local sales representative to check the availability in your country.
Turbo-Elite is distributed by LifeSystems in Australia and New Zealand.
Always read the label and follow the directions for use.
Philips medical devices should only be used by physicians and teams trained in interventional techniques, including training in the use of this device.
Philips reserves the right to change product specifications without prior notification.
©2025 Koniklijke Philips N.V. All rights reserved. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.