Turbo-Elite laser atherectomy catheter captures the power of ultraviolet light to provide a versatile and reliable tool for treating multiple lesion morphologies within PAD lesions. Utilizing laser's unique mechanism of action, Turbo-Elite is capable of powering through the most challenging restenoses and occlusions.

Specifications

Model Number 410-152 Peripheral Over-the-Wire Catheter
Model Number 410-152 Peripheral Over-the-Wire Catheter
Catheter diameter
  • 0.9 mm
Vessel diameter
  • ≥1.4 mm
Max guidewire compatibility
  • 0.014”
Sheath compatibility
  • 4F
Max tip outer diameter
  • 0.038”
Max shaft outer diameter
  • 0.047”
Working length
  • 150 cm
Fluence
  • 30-80 mJ/mm²
Repetition
  • 25-80 Hz
Model Number 414-151 Peripheral Over-the-Wire Catheter
Model Number 414-151 Peripheral Over-the-Wire Catheter
Catheter diameter
  • 1.4 mm
Vessel diameter
  • ≥2.1 mm
Max guidewire compatibility
  • 0.014”
Sheath compatibility
  • 5F
Max tip outer diameter
  • 0.055”
Max shaft outer diameter
  • 0.056”
Working length
  • 150 cm
Fluence
  • 30-60 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 417-152 Peripheral Over-the-Wire Catheter
Model Number 417-152 Peripheral Over-the-Wire Catheter
Catheter diameter
  • 1.7 mm
Vessel diameter
  • ≥2.6 mm
Max guidewire compatibility
  • 0.018”
Sheath compatibility
  • 5F
Max tip outer diameter
  • 0.068”
Max shaft outer diameter
  • 0.069”
Working length
  • 150 cm
Fluence
  • 30-60 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 420-006 Peripheral Over-the-Wire Catheter
Model Number 420-006 Peripheral Over-the-Wire Catheter
Catheter diameter
  • 2 mm
Vessel diameter
  • ≥3.0 mm
Max guidewire compatibility
  • 0.018”
Sheath compatibility
  • 6F
Max tip outer diameter
  • 0.080”
Max shaft outer diameter
  • 0.081”
Working length
  • 150 cm
Fluence
  • 30-60 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 423-001 Peripheral Over-the-Wire Catheter
Model Number 423-001 Peripheral Over-the-Wire Catheter
Catheter diameter
  • 2.3 mm
Vessel diameter
  • ≥3.5 mm
Max guidewire compatibility
  • 0.018”
Sheath compatibility
  • 7F
Max tip outer diameter
  • 0.091”
Max shaft outer diameter
  • 0.091”
Working length
  • 120 cm
Fluence
  • 30-60 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 425-011 Peripheral Over-the-Wire Catheter
Model Number 425-011 Peripheral Over-the-Wire Catheter
Catheter diameter
  • 2.5 mm
Vessel diameter
  • ≥3.8 mm
Max guidewire compatibility
  • 0.018”
Sheath compatibility
  • 8F
Max tip outer diameter
  • 0.101”
Max shaft outer diameter
  • 0.102”
Working length
  • 110 cm
Fluence
  • 30-45 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 423-135 Peripheral Over-the-Wire Catheter
Model Number 423-135 Peripheral Over-the-Wire Catheter
Catheter diameter
  • 2.3 mm
Vessel diameter
  • ≥3.5 mm
Max guidewire compatibility
  • 0.035”
Sheath compatibility
  • 7F
Max tip outer diameter
  • 0.091”
Max shaft outer diameter
  • 0.091”
Working length
  • 125 cm
Fluence
  • 30-60 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 423-135 Peripheral Over-the-Wire Catheter
Model Number 423-135 Peripheral Over-the-Wire Catheter
Repetition rate
  • 25-80Hz
Model Number 425-135 Peripheral Over-the-Wire Catheter
Model Number 425-135 Peripheral Over-the-Wire Catheter
Catheter diameter
  • 2.5 mm
Vessel diameter
  • ≥3.8 mm
Max guidewire compatibility
  • 0.035”
Sheath compatibility
  • 8F
Max tip outer diameter
  • 0.101”
Max shaft outer diameter
  • 0.102”
Working length
  • 112 cm
Fluence
  • 30-60mJ/mm²
Model Number 410-154 Peripheral Rapid Exchange Catheter
Model Number 410-154 Peripheral Rapid Exchange Catheter
Catheter diameter
  • 0.9 mm
Vessel diameter
  • ≥1.4 mm
Max guidewire compatibility
  • 0.014”
Sheath compatibility
  • 4F
Max tip outer diameter
  • 0.038”
Max shaft outer diameter
  • 0.049”
Working length
  • 150 cm
Fluence
  • 30-80 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 414-159 Peripheral Rapid Exchange Catheter
Model Number 414-159 Peripheral Rapid Exchange Catheter
Catheter diameter
  • 1.4 mm
Vessel diameter
  • ≥2.1 mm
Max guidewire compatibility
  • 0.014”
Sheath compatibility
  • 5F
Max tip outer diameter
  • 0.057”
Max shaft outer diameter
  • 0.062”
Working length
  • 150 cm
Fluence
  • 30-60 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 417-156 Peripheral Rapid Exchange Catheter
Model Number 417-156 Peripheral Rapid Exchange Catheter
Catheter diameter
  • 1.7 mm
Vessel diameter
  • ≥2.6 mm
Max guidewire compatibility
  • 0.014”
Sheath compatibility
  • 6F
Max tip outer diameter
  • 0.069” in
Max shaft outer diameter
  • 0.072”
Working length
  • 150 cm
Fluence
  • 30-60 mJ/mm²
Repetition rate
  • 25-80 Hz
Model Number 420-159 Peripheral Rapid Exchange Catheter
Model Number 420-159 Peripheral Rapid Exchange Catheter
Catheter diameter
  • 2 mm
Vessel diameter
  • ≥3.0 mm
Max guidewire compatibility
  • 0.014”
Sheath compatibility
  • 7F
Max tip outer diameter
  • 0.080”
Max shaft outer diameter
  • 0.084”
Working length
  • 150 cm
Fluence
  • 30-60 mJ/mm²
Repetition rate
  • 25-80 Hz
  • 1. Dippel et al. Excimer laser recanalization of femoropopliteal lesions and 1-year patency: results of the CELLO registry. J Endovasc Ther. 2009 Dec;16(6):665-75.
  • 2. Zeller et al. J Endovasc Ther. Photoablation using the turbo-booster and excimer laser for in-stent restenosis treatment: twelve-month results from the PATENT study. J Endovasc Ther. 2014 Feb;21(1):52-60
  • 3. Dippel et al. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis). JACC Cardiovasc Interv. 2015 Jan;8(1 Pt A):92-101
  • 4. Laird et al.  Limb Salvage Following Laser-Assisted Angioplasty for Critical Limb Ischemia: Results of the LACI Multi­center Trial. J Endovasc Ther. 2006 Feb;13(1):1-11
  • *When used with Turbo-Tandem and PTA
  • **Images courtesy of Dr. Devendra Amin
BannerImage

Let us know how we can help

We are always interested in engaging with you

1
Select your area of interest
2
Contact details
1
2
Contact details

Submit a sales inquiry

Please provide some information below and we can help direct you to the right person.
We work with partners and distributors who may contact you about this Philips product on our behalf.
*
*
*
*
*
*
*
*
*
*
BannerImage

Let us know how we can help

We are always interested in engaging with you

1
Select your area of interest
2
Contact details
1
2
Contact details

Submit a sales inquiry

Please provide some information below and we can help direct you to the right person.
We work with partners and distributors who may contact you about this Philips product on our behalf.
*
*
*
*
*
*
*
*
*
*