Reusable, pediatric/small adult SpO₂ glove sensor
Pulse oximetry supplies
HCM1192ASupplies
  • Philips SpO2 pediatric glove sensor M1192A pull force test
  • Alternative product photograph
  • Standard product photograph

Reusable, pediatric/small adult SpO₂ glove sensor

Pulse oximetry supplies
HCM1192ASupplies
The reusable Philips M1192A glove finger SpO₂ sensor is specifically designed for small fingers, and fits pediatric and small adult patients weighing 15-50 kg (33-110 lbs). Its durable, silicone form is manufactured without latex. It comes with a comprehensive warranty.* *Check with your local sales representative for the warranty details in your area.

Features
Durable and validated
All our SpO₂ sensors undergo demanding testing to make sure they meet Philips standards.
Designed for FAST-SpO₂
Our pulse oximetry sensors are designed specifically for Philips proprietary FAST-SpO₂ (Fourier Artifact Suppression Technology) algorithm. Together, they reduce effects from patient movement, electronic interference, ambient light and low perfusion.
Specifications
  • SpO2 Sensor
    Patient Application
    Child
    Application Site
    Finger
    Adapter Cable Compatibility
    M1941A
    Recommended Patient Weight
    15 - 50 kg (33 - 110 lbs)
    Cable Length
    1.5 m (4.9')
  • Product details
    Product Category
    SpO2
    Use with Non-Philips Healthcare Equipment
    No
    Use with Philips Healthcare Equipment
    862108, 862231, 862439, 862474, 862478, 863063, 863064, 863065, 863066, 863068, 863071, 863072, 863073, 863074, 863077, 863080, 863081, 863082, 863085, 863086, 863087, 863088, 863264, 863265, 863266, 863276, 863278, M1020A, M1020B, M1350B, M1350C, M2600A, M2703A, M2705A, M3000A, M3001A, M3002A, M3535A, M3536A, M3536M, M4735A, M8102A, M8105A, M8105AT, M8105AS
    Product Type
    Sensor
    CE Certified
    Yes
    Single-Patient Use OR Multi-Patient Use
    Multi-Patient Use
    Package Weight
    .045
    Not manufactured with natural rubber latex
    Yes
    Packaging Unit
    1 sensor
    Sterile OR Non-Sterile
    Non-Sterile
    Minimum Shelf Life
    None

Documentation

SpO₂ sensors that last
PDF|649.95 KB
Reusable sensors that last
PDF|831.63 KB
Studies of new generation Pulse Oximetry technologies
PDF|240.80 KB
Product Brochure
PDF|1.86 MB


Related products

  • Single-patient, neonatal/infant/adult SpO₂ wrap sensor Pulse oximetry supplies
    The Philips M1133A pulse oximetry sensor delivers continuous, noninvasive measurement of arterial oxygen saturation. Designed for multi-day, single-patient use, the M1133A wrap sensor is made of soft and flexible material and is manufactured without latex. It can be placed around the hand or foot to measure pulse oximetry on patients weighing less than 3 kg (6.6 lbs), as well as on the big toe or thumb of children from 10-20 kg (22-44 lbs), and on any finger except the thumb on patients over 40 kg (88 lbs).
  • Reusable adult SpO₂ glove sensor Pulse oximetry supplies
    Manufactured without latex, comfortable and easy-to-clean, the Philips M1191B reusable SpO₂ glove sensor delivers high signal quality to provide continuous measurement of oxygen saturation. It is designed for use on the fingers of adults greater than 50 kg (110 lbs). With a comprehensive warranty, the M1191B sensor withstands the rigors of repeated use.
  • Reusable adult SpO₂ glove sensor with long cable Pulse oximetry supplies
    M1191BL SpO₂ glove sensor features a long, 3-meter (118”) cable to accommodate a variety of bed/room configurations. It is designed for use on the fingers of adults greater than 50 kg (110 lbs). Manufactured without latex, durable and comfortable, the M1191BL is a cost-effective, versatile choice for continuous oxygen saturation measurement.
  • Reusable adult SpO₂ glove sensor with mid-point connector Pulse oximetry supplies
    The Philips M1191T SpO₂ glove sensor features a mid-point connector for efficient transfer from a bedside to a transport or mobile patient monitor. It is designed for use on the fingers of adults greater than 50 kg (110 lbs). This durable, comfortable sensor is manufactured without latex and supports cost-effective oxygen saturation measurement.
  • Extension cable Pulse oximetry supplies
    Philips M1941A extension cable is an 8-pin to 8-pin input connector. It is 2.0 m (6.56 ft) long is compatible with a wide variety of Philips products. It is not manufactured with natural rubber latex.
  • Multi-patient, 8-pin to 9-pin D-sub adapter cable, 1.1 m (3.6 ft) Pulse oximetry supplies
    Designed for use with Philips SpO₂ monitors and sensors, the M1943A 8-pin adapter cable is 1.1 m (3.6 ft) in length and features a D-sub connector. It adapts 9-pin sensors to 8-pin sockets. It can be used with these sensors: M1131A, M1132A, M1133A, M1134A, M1140A, M1191T, M1192T, M1193T and M1196T.
Disclaimer
Product may not be available in all geographies, please check with your Philips representative for complete portfolio availability.