Advanced life support solutions

HeartStart MRx

Monitor/Defibrillator for emergency care

Rugged, reliable, and easy-to-use, the HeartStart MRx with the DXL 12-Lead ECG algorithm, provides industry-leading patient monitoring capabilities, exceptional diagnostic measurements, proven resuscitation therapies, and CPR guidance.

Rugged, reliable, and easy-to-use, the HeartStart MRx with the DXL 12-Lead ECG algorithm, provides industry-leading patient monitoring capabilities, exceptional diagnostic measurements, proven resuscitation therapies, and CPR guidance.

Contact information

* This field is mandatory
*

Contact details

*
*
*

Company details

*
*
*
*
*

Inquiry details

By specifying your reason for contact we will be able to provide you with a better service.
*
*
For a U.S sales representative please call 1-800-225-0230. For non-US purchasing, training, support and more click the button to contact us.

Contact information

* This field is mandatory
*

Contact details

*
*
*

Company details

*
*
*
*
*

Inquiry details

By specifying your reason for contact we will be able to provide you with a better service.
*
*
Features
Built to endure, designed to evolve
Built to endure, designed to evolve

Built to endure, designed to evolve

The HeartStart MRx is built tough—tough enough to endure environmental conditions created by water, vibrations, mechanical shocks, drops, and electromagnetic activity. Plus it’s built on a scalable platform, so you can upgrade easily and take advantage of Philips advancements while retaining the same footprint and weight.
Easy to use, fast to respond
Easy to use, fast to respond

Easy to use, fast to respond

The HeartStart MRx has an easy-to-use interface that helps you respond quickly. Communication and collaboration with your hospital care teams is simple. And when it’s time to hand-off from a HeartStart FR3, you don’t need to change pads.
Rich clinical information, driving patient care

Rich clinical information, driving patient care

With the DXL 12-Lead ECG algorithm, the HeartStart MRx gives advanced STEMI decision support. There are predictive tools that show the probability that the patient is experiencing acute ischemia or the likely outcome of AMI. These tools help you make confident decisions to speed triage.
“When I first purchased the MRx monitors I knew I was getting a great piece of equipment. What I didn’t know is that Philips Healthcare would transition from a vendor to a partner in saving lives every day. Philips has continually provided support and knowledge that put them first in class. Their willingness to work with organizations to accomplish a task is something I will always appreciate.”

-Brian Rogers EMS Training Officer Henderson Fire Department Chief Operating Officer/Principle Community Ambulance

Features

  • Seamless wireless data transmission of 12-lead ECGs with optional Wireless Link.
  • Easy to use interface.
  • Large color screen displays 4 waveforms and numerics, or all 12 leads and numerics.
  • Flexible Event Summary allows configuration of the data you want.
  • Time Insensitive Predictive Instrument (ACI-TIPI) helps predict probability of acute ischemia.
  • Thrombolytic Predictive Instrument (TPI) helps predict patient outcome with and without thrombolytic therapy.
  • SMART Biphasic therapy for high first shock efficacy for long downtime SCA patients.
  • Quick Shock for fast time to shock.

Specifications

Physical dimensions
Physical dimensions
Size with external paddles
  • 12.4" (W) x 7.7" (D) x 13.4" (H) (313 mm x 195 mm x 340 mm) "/ mm
Weight
  • 13.2 lbs. (6 kg): base unit with 1 battery/pads and pads cable.13 lbs. (5.9 kg) with optional 75 mm strip chart printer.Paddle tray and external standard paddles add less than 2.5 lbs. (1.1 kg).Carrying case adds 4.1 lbs. (1.86 kg). lbs/ kg
Physical dimensions Defibrillator model HeartStart MRx (M3536A)
Physical dimensions Defibrillator model HeartStart MRx (M3536A)
Size without external paddles
  • 12.4" (W) x 7.7" (D) x 11.7" (H) (313 mm x 195 mm x 295 mm) "/ mm
Battery
Battery
Type
  • 6.3 Ah, 14.8 V, rechargeable lithium ion Ah/V
Dimensions
  • 6.5" (H) x 3.8" (W) x 1.6" (D) (165 mm x 95 mm x 42 mm) "/ mm
Capacity
  • At least 5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring.With NBP every 15 minutes on one new fully charged battery hours
Weight
  • 1.6 lb. (0.73 kg) lb/ kg
Charge Time
  • Approximately 3 hours from fully depleted to 100%. 90 minutes from fully depleted to 80% hours/%
Capacity(b)
  • At least 3.5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring. With NBP every 15 minutes and pacing at 180 ppm at 160 mA on one new fully charged battery hours
End-tidal CO2
End-tidal CO2
Range
  • 0 to 99 mmHg mmHg
Resolution
  • 1 mmHg (0.1 kPa) mmHg/kPa
Sample Size
  • 50 ml per minute ml
Alarm Range(h)
  • Low Limit: 10 to 95 mmHg (Adult/Pediatric) mmHg
Alarm Range(i)
  • High Limit: 20 to 100 mmHg (Adult/Pediatric) mmHg
Power supply
Power supply
Type
  • 6.3 Ah, 14.8 V, rechargeable lithium ion Ah/V
Environmental & physical requirements
Environmental & physical requirements
Solids/Water resistance
  • IP24
Operating temperature
  • 0º - 45º C (32º - 113º F) ° C/° F
Storage temperature
  • -20 - 70º C (-4º - 158º F) ° C/° F
Operating humidity
  • 0% to 95% relative %
Operating altitude
  • 0 to 15000 ft (0 to 4500 m) ft/ m
Storage altitude
  • 0 to 15000 ft (0 to 4500 m) ft/ m
Mechanical shock
  • Bump: IEC 68-2-29
  • Freefall: IEC 68-2-32
Operating vibration
  • MIL STD 810E 514.4 Category 6 Helicopter
General storage vibration
  • UH60 Non-Operating: IEC 68-2-6 Swept Sine Vibration and IEC 68-2-64 Random Vibration
Safety
  • Meets EN 60601-1, UL 2601-1/CSA C22.2 No. 601-1
Display
Display
Type
  • TFT color LCD
Dimensions
  • 8.4’’ diagonal (128 mm x 171 mm) "/ mm
Resolution
  • 1 mmHg (0.1 kPa) mmHg/kPa
Type
  • TFT color LCD
Resolution
  • 480 x 640 pixels (VGA)
Wave Viewing Time
  • 5 seconds (ECG) seconds
Defibrillation
Defibrillation
Waveform
  • Truncated Exponential Biphasic.Waveform parameters adjusted as a function of patient impedance.
Output Energy
  • Manual (selected): 1-10/15/20/30/50/70/100/120/150/170/200 Joules into a 50 Ohm loadAED Mode (single energy output): 150 Joules into a 50 ohm load. Joules/Ohm
Charge Time
  • Less than 5 seconds to 200 Joules with a new/ fully charged lithium ion battery at 25º C
Shock Delivery
  • Via multifunction defib electrode pads or paddles
Shock-to-Shock Cycle Time
  • Typically less than 20 seconds
Minimum Patient Impedance Range
  • 15 Ohm (internal defibrillation); 25 Ohm (external defibrillation) Ohm
Maximum Patient Impedance Range
  • 180 Ohm
AED Mode
  • Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines
Noninvasive Blood Pressure
Noninvasive Blood Pressure
Pressure Range(a)
  • Systolic: 40 to 260 mmHg
Pressure Range(b)
  • Diastolic: 20 to 200 mmHg
Initial Pressure
  • Adult: 160 mmHg and Pediatric: 120 mmHg
Maximum Pressure
  • 280 mmHg
Alarm Range(d)
  • Systolic high limit: 30 - 270 (Adult) and 35 - 180 (Pediatric)
Alarm Range(e)
  • Systolic low limit: 30 - 265 (Adult) and 30 - 175 (Pediatric)
Alarm Range(f)
  • Diastolic high limit: 18 - 240 (Adult) and 18 - 150 (Pediatric)
Alarm Range(g)
  • Diastolic low limit: 10 - 240 (Adult) and 10 - 145 (Pediatric)
Strip Chart Recorder
Strip Chart Recorder
Recorder(a)
  • Standard: 50 mm (paper width) thermal array printer mm
Recorder(b)
  • Optional: 75 mm (paper width) thermal array printer mm
Continuous ECG Strip
  • Prints primary ECG lead with event annotations and measurements in real-time or with 10-second delay
Auto Printing
  • Recorder can be configured to print marked events/charge/ shock and alarms
Reports
  • Event Summary, 12-Lead/Operational Check/ Configuration/Status Log and Device Information
Paper Size
  • 1.97” (50 mm) W by 100 ft. (30 m) L and 2.95” (75 mm) W by 100 ft. (30 m) L "/ft/mm/m
Data storage
Data storage
Internal
  • 12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports
Data Card
  • 12 hours of continuous ECG waveforms and events.Plus 50 12-lead ECG reports on a CompactFlash memory card
ECG and arrhythmia monitoring
ECG and arrhythmia monitoring
Input
  • Up to 4 ECG waves displayed and up to 3 ECG waves print simultaneously.
Leads
  • Lead I, II, or III obtained through 3-lead ECG cable and separate monitoring electrodes.With 5-lead cable, obtain leads I/II/III/aVR/aVL/ aVF or V.Pads ECG obtained through 2 multifunction defibrillation electrode pads.
Lead Fault
  • ‘Lead Off ’ message and dashed line displayed if an electrode or lead wire becomes disconnected.
Pads Fault
  • Dashed line displayed if a pad becomes disconnected.
Heart Rate Display
  • Digital readout on display 15 to 300 bpm with accuracy ±10% bpm/%
Heart Rate/Arrhythmia Alarms
  • HR/Asystole/VFIB/VTACH/VTACH/extreme tachycardia/extreme bradycardia/PVC rate.
ECG Size
  • 2.5/5/10/20/40 mm/mV autogain mm/mV
SpO2 pulse oximetry
SpO2 pulse oximetry
Range
  • 0 to 100 %
Resolution
  • 0.01 %
Alarm Range(a)
  • Low Limit: 50 to 99% (Adult/Pediatric) %
Alarm Range(b)
  • High Limit: 51 to 100% (Adult/Pediatric) %
Alarm Delay
  • 10 seconds
12-Lead ECG
12-Lead ECG
Input
  • 12-Lead cable: leads I/II/III/aVR/aVL/ aVF and V/C1-V/C6
Display View
  • All 12-lead ECG waves display simultaneously
Strip Recorder
  • All 12-leads print on the strip chart printer in 3x4 format
Transmission
  • CompactFlash data card; Bluetooth® dial-up Internet connection, Bluetooth® FTP
CPR feedback and measurement
CPR feedback and measurement
Compression Depth
  • Target: -1.50 to -2.00" (-38 to -51 mm) "/ mm
Compression Rate
  • Target: 90 to 120 cpm cpm
Ventilation Volume
  • Graphic indicator: empty/one-third full/two-thirds full/full
Ventilation Rate(a)
  • Target for breaths delivered before 60 seconds since last compression: 6 to 16 vpm seconds/vpm
Ventilation Rate(b)
  • Target for breaths delivered beyond 60 seconds since last compression: 9 to 16 vpm seconds/vpm
Noninvasive pacing
Noninvasive pacing
Current Pulse Amplitude
  • 10 mA to 160 mA (5 mA resolution); accuracy 10 mA to 50 mA ± 5 mA, 50 mA - 160 m A ± 10% mA
Pulse Width
  • 40 ms with ± 10% accuracy ms/%
Rate
  • 30 ppm to 180 ppm (10 ppm increments); accuracy ± 1.5% ppm
Modes
  • Demand or Fixed Rate
Refractory Period
  • 340 msec (30 to 80 ppm); 240 msec (90 to 180 ppm) msec/ppm

Supplies list

 

Supplies for your Philips EMS equipment are as rugged, reliable and affordable as the devices themselves. Below, find the key supplies you need for your HeartStartMRx monitor/defibrillator. Some are available on our eStore and all may be ordered by phone.

 

View a complete list of supplies for our EMS products

 

Product number

 

Supply name

 

Description

 

Category

 

989803176161

 

Most popular

5-Lead Shielded Limb Snap

 

Rugged lead sets include labels that can be seen in low-light environments

 

Leads

 

989803176171

 

Most popular

5-Lead Shielded Chest Snap

 

Rugged lead sets include labels that can be seen in low-light environments

 

Leads

 

989803166021

 

Most popular

Adult/Child Preconnect Pads

 

Pads

 

M4737A

 

Most popular

MRx Display Cover

 

Accessories

 

M3716A

 

Adult/Child Radiolucent Pads

 

Pads

 

M3713A

 

Adult/Child Plus

 

Pads

 

M3717A

 

Infant Plus Pads

 

Pads

 

M3538A

 

Lithium Ion Battery Module

 

Power

 

M5529A

 

DC Power Module

 

Power

 

40401B

 

Traditional Reusable NBP Cuff

 

Pediatric, 1 cuff

 

NIBP

 

M3725A

 

HeartStart 50 ohm

Test Load

 

Test Load

 

 

M1920A

 

Filter Line Set

 

Adult/Pediatric (25 sets/case)

 

EtCO2

 

989803158661

 

Replacement Pads/CPR

Meter Cable

 

Cables

 

M1663A

 

10-Lead ECG Patient Trunk Cable, 12-pin Accessories

 

Cables

Support