Diagnostics (X-Ray, CT, MR)

Reference

Symbol

Name

Description

Note

X-Ray

Biplane Fluoroscopy

Biplane Fluoroscopy

Selects biplane fluoroscopy

combines IEC 60417 5330 and 5364

X-Ray

Missing Symbol

Fluoroscopy

Selects fluoroscopy acquisition

IEC 60417 5330 (the eye) plus other elements

X-Ray

Missing Symbol

Fluoroscopy Flavor 1

Selects the fluoroscopy flavor

IEC 60417 5330 (the eye) plus other elements. May appear as

Missing Symbol

X-Ray

Missing Symbol

Fluoroscopy Flavor 2

Selects the fluoroscopy flavor

IEC 60417 5330 (the eye) plus other elements. May appear as

two dashes under an eye

X-Ray

Missing Symbol

Fluoroscopy Flavor 3

Selects the fluoroscopy flavor

IEC 60417 5330 (the eye) plus other elements. May appear as

three dashes under an eye

X-Ray

Missing Symbol

Frontal Fluoroscopy

Selects fluoroscopy on the frontal channel

Combines IEC 60417 5330 and 5338

IEC 60417-5330

icon image

Radioscopy

To identify controls or indicators for radioscopy (fluoroscopy).

May appear as

Missing Symbol

IEC 60417-5337

icon image

X-ray tube

To indicate a reference to the X-ray tube, for example to identify the surface of a component such as a focused anti-scatter grid, that has to be oriented towards the X-ray tube.

IEC 60417-5338

Xray source

X-ray source assembly

To indicate a reference to an X-ray source assembly.

X-Ray

Lateral Fluoroscopy

Lateral Fluoroscopy

Selects fluoroscopy on the lateral channel

IEC 60417-5339

Xray source assembly

X-ray source assembly, emitting

To indicate the emission or the imminent emission of X-radiation.

IEC 60417-5364

icon image

Radiodiagnostic simultaneous bi-plane operation

To indicate a reference to simultaneous operation of two X-ray tubes.

IEC 60417-5376

icon image

X-ray image intensifier

To indicate a reference to an X-ray image intensifier.

May appear as:

icon image

IEC 60417-5385

icon image

Beam limiting device, open

To identify controls for opening the beam limiting device or to identify its partially or fully open state.

May appear as:

beam limiting device dark

IEC 6078-5386

beam limiting device closed

Beam limiting device, closed

To identify controls for closing the beam limiting device or to identify its closed state.

May appear as:

beam limiting closed

IEC 60417-5392

icon image

Patient support, tilting

To identify the control for tilting the patient support or examination table.

May appear as:

icon image
tilt right
tilt up and down

IEC 60417-5398

patient cradle

Patient cradle, rotation about its longitudinal axis

To identify the control for rotation of the patient cradle about its longitudinal axis

May appear as:

cradle left arrow
cradle right arrow

IEC 60417-5395

icon image

Patient support, orthogonal movement to its plane

To identify the control for the movement orthogonal to the plane of the patient support (table height).

May appear as:

icon image

IEC 60417-5396

icon image

Patient support, movements in its plane

To identify controls for movements in the plane of the patient support.

May appear as:

icon image

62570-7.3.3

MR Unsafe symbol

MR Unsafe

To identify an item which poses unacceptable risks to the patient, medical staff or other persons within the MR environment.