1
Products

Diagnostics (X-Ray, CT, MR)

Reference
Symbol
Name
Definition
Note
X-Ray
Biplane Fluoroscopy
Biplane Fluoroscopy
Selects biplane fluoroscopy
combines IEC 60417 5330 and 5364
X-Ray
Missing Symbol
Fluoroscopy
Selects fluoroscopy acquisition
IEC 60417 5330 (the eye) plus other elements
X-Ray
Missing Symbol
Fluoroscopy Flavor 1
Selects the fluoroscopy flavor
IEC 60417 5330 (the eye) plus other elements. May appear as
Missing Symbol
X-Ray
Missing Symbol
Fluoroscopy Flavor 2
Selects the fluoroscopy flavor
IEC 60417 5330 (the eye) plus other elements. May appear as
two dashes under an eye
X-Ray
Missing Symbol
Fluoroscopy Flavor 3
Selects the fluoroscopy flavor
IEC 60417 5330 (the eye) plus other elements. May appear as
three dashes under an eye
X-Ray
Missing Symbol
Frontal Fluoroscopy
Selects fluoroscopy on the frontal channel
Combines IEC 60417 5330 and 5338
IEC 60417-5330
icon image
Radioscopy
To identify controls or indicators for radioscopy (fluoroscopy).
May appear as
Missing Symbol
IEC 60417-5337
icon image
X-ray tube
To indicate a reference to the X-ray tube, for example to identify the surface of a component such as a focused anti-scatter grid, that has to be oriented towards the X-ray tube.
IEC 60417-5338
Xray source
X-ray source assembly
To indicate a reference to an X-ray source assembly.
X-Ray
Lateral Fluoroscopy
Lateral Fluoroscopy
Selects fluoroscopy on the lateral channel
IEC 60417-5339
Xray source assembly
X-ray source assembly, emitting
To indicate the emission or the imminent emission of X-radiation.
IEC 60417-5364
icon image
Radiodiagnostic simultaneous bi-plane operation
To indicate a reference to simultaneous operation of two X-ray tubes.
IEC 60417-5376
icon image
X-ray image intensifier
To indicate a reference to an X-ray image intensifier.
May appear as:
icon image
IEC 60417-5385
icon image
Beam limiting device, open
To identify controls for opening the beam limiting device or to identify its partially or fully open state.
May appear as:
beam limiting device dark
IEC 6078-5386
beam limiting device closed
Beam limiting device, closed
To identify controls for closing the beam limiting device or to identify its closed state.
May appear as:
beam limiting closed
IEC 60417-5392
icon image
Patient support, tilting
To identify the control for tilting the patient support or examination table.
May appear as:
icon image
tilt right
tilt up and down
IEC 60417-5398
patient cradle
Patient cradle, rotation about its longitudinal axis
To identify the control for rotation of the patient cradle about its longitudinal axis
May appear as:
cradle left arrow
cradle right arrow
IEC 60417-5395
icon image
Patient support, orthogonal movement to its plane
To identify the control for the movement orthogonal to the plane of the patient support (table height).
May appear as:
icon image
IEC 60417-5396
icon image
Patient support, movements in its plane
To identify controls for movements in the plane of the patient support.
May appear as:
icon image
62570-7.3.3
MR Unsafe symbol
MR Unsafe
To identify an item which poses unacceptable risks to the patient, medical staff or other persons within the MR environment.